ROVIQ Lab Results: HPLC Purity by Lot
ROVIQ sent a sample of each lot below to an independent laboratory, Freedom Diagnostics, for HPLC-UV purity and LC-MS identity testing. The laboratory received the samples on July 13, 2026 and reported on July 16, 2026. All 19 lots below had their identity confirmed by LC-MS, and their HPLC-UV purity ranged from 99.09% to 99.97%, as reported by the laboratory. Each row links to the full Certificate of Analysis (COA).
Results by lot
| Product | Purity (HPLC-UV) | Identity (LC-MS) | Lot | Accession # | COA |
|---|---|---|---|---|---|
| AOD-9604 5mg | 99.84% | Confirmed | AOD5-260703-A01 | 2607130897 | |
| CJC-1295 / Ipamorelin 10mg Ipamorelin / CJC-1295 | 99.81% | Confirmed | CI10-260703-A01 | 2607130900 | |
| GHK-Cu 100mg | 99.82% | Confirmed | GH10-260703-A01 | 2607130910 | |
| GLOW 70mg GHK-Cu / TB-500 / BPC-157 | 99.83% | Confirmed | GL70-260703-A01 | 2607130908 | |
| Glutathione 1500mg | 99.97% | Confirmed | GT15-260703-A01 | 2607130892 | |
| Ipamorelin 10mg | 99.81% | Confirmed | IP10-260703-A01 | 2607130906 | |
| KLOW 80mg GHK-Cu / KPV / TB-500 / BPC-157 | 99.49% | Confirmed | KL80-260703-A01 | 2607130909 | |
| MOTS-c 40mg | 99.58% | Confirmed | MC40-260703-A01 | 2607130898 | |
| NAD+ 1000mg | 99.81% | Confirmed | ND10-260703-A01 | 2607130893 | |
| PT-141 10mg | 99.97% | Confirmed | PT10-260703-A01 | 2607130896 | |
| Retatrutide 20mg | 99.85% | Confirmed | RT20-260703-A01 | 2607130904 | |
| Retatrutide 30mg | 99.85% | Confirmed | RT30-260703-A01 | 2607130899 | |
| Selank 10mg | 99.58% | Confirmed | SL10-260703-A01 | 2607130901 | |
| Semax 10mg | 99.30% | Confirmed | SX10-260703-A01 | 2607130905 | |
| Sermorelin 10mg | 99.09% | Confirmed | SM10-260703-A01 | 2607130907 | |
| Tesamorelin 10mg | 99.86% | Confirmed | TS10-260703-A01 | 2607130894 | |
| Tirzepatide 30mg | 99.86% | Confirmed | TZ30-260703-A01 | 2607130895 | |
| Wolverine Blend 10mg Thymosin Beta-4 / BPC-157 | 99.47% | Confirmed | WV10-260703-A01 | 2607130902 | |
| Wolverine Blend 20mg Thymosin Beta-4 / BPC-157 | 99.49% | Confirmed | WV20-260703-A01 | 2607130903 |
Figures are republished exactly as reported by Freedom Diagnostics; ROVIQ has not re-analysed the samples. One sample per lot, tested once; a result describes that lot only. For blends, the laboratory reports one purity figure for the vial and confirms the identity of each listed component. NAD+ is a dinucleotide, not a peptide, and was tested with the same method. Bacteriostatic water is not a peptide and is not tabulated here; its COA is published separately.
How to read these results
On these COAs, purity is reported as area-percent purity from HPLC with UV detection: the area of the main peak divided by the total area of all integrated peaks. Identity is reported from LC-MS, which measures the mass of what came off the column and compares it with the expected compound. The two answer different questions: a high purity figure alone does not establish identity, and a confirmed identity alone does not say how clean the sample is.
To check a row against its source, open the COA and confirm that the product name, lot number and accession number match. The guides below walk through each section of a COA and its chromatogram.